Printer Interface Information RS-232 Cable Diagrams for Tally Printers

Applies to models MT130/131, MT150/151, MT160/180, MT230, MT290, MT330/340, MT350/360/MT380, MT460/490, and MT1000 series:

PC-XT                Tally Printer
(DB-25P)           (DB-25S)

2 ----------------------- 3
3-----------------------  2
5 ----------------------- 11 or 19
7 ----------------------- 7
6 --| (jumper)
20-|

PC-AT               Tally Printer
(DB-9P)             (DB-25S)

2 ----------------------- 2
3 ----------------------- 3
5 ----------------------- 7
8 ----------------------- 11 or 19
4 --| (jumper)
6 --| 

:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: 

The following diagrams apply to models MT80, MT81, MT82, MT85/86, MT87/88, MT90, MT904, MT905, MT906, MT908, MT910, MT911, T9008, T9012, T9030/9031/9040,MT645/661/691, T6045, T6082/6092:

 PC-XT               Tally Printer
(DB-25P)             (DB-25S)

2 ----------------------- 3
3 ----------------------- 2
                                4 --| (jumper) [MT905 only]
                                5 --|
5 ----------------------- 20
7 ----------------------- 7
6 --| (jumper)
20-|

PC-AT                Tally Printer
(DB-9P)                (DB-25S)

2 ----------------------- 2
3 ----------------------- 3
                                4 --| (jumper) [MT905 only]
                                5 --|
5 ----------------------- 7
8 ----------------------- 20
4 --| (jumper)
6 --|